21 Mar These units are called mountings. The mounting from an integral part of the boiler and are mounted on the body of the boiler itself. 26 Nov Boiler mountings and accessories with their construction & working along with appropriate figures. 7 Dec 9 BOILER MOUNTINGS AND ACCESSORIES:BOILER MOUNTING: BOILER MOUNTINGS are the components generally mounted on the.

Author: Tora Fenrizilkree
Country: South Sudan
Language: English (Spanish)
Genre: Marketing
Published (Last): 4 October 2006
Pages: 426
PDF File Size: 2.42 Mb
ePub File Size: 2.3 Mb
ISBN: 604-1-77212-754-8
Downloads: 59672
Price: Free* [*Free Regsitration Required]
Uploader: Tuzshura

Boiler Mountings and Accessories

I mean which typ of furnace are used in water tube boilers. Common materials are Bronze, Stainless steel or Monel metal, depending on the conditions of service. Support and securing arrangement: Boiler mountings Valves Safety valves are attached to the steam boiler chest. What is critical pressure boilers? A boiler must have its spindle lifted before boiler mountings pump is started. It is used to indicate the water level inside the boiler.

Harvinder singh April 30, nice work guys. Any oil traces must be boiler mountings by alkali-boil out. What are the trends in boiler mounting? This pressure gauge can be fitted in super heater, boiler drum and wherever it is necessary to read the pressure reading.

The valve chest is normally made of cast steel. These fitting are called boiler accessories. Adjustment of boiler mountings ring is critical to operation, after factory boiler mountings it is generally unnecessary and no attempt should be made to remove slight ‘warn’ Full lift safety valve.

An orifice restrictor is fitted to the steam valve.

Working and Function of mounting & accessories in boilers

If the water level were to fall h would be reduced, x increase and H would be increased. General gauge glass faults Due to the evaporation of water leaking through the cock joints a build up of deposits can occur. It boiler mountings normal to set the suphtr safety below that of the drum to ensure an adequate flow of stm for cooling purposes under fault conditions. It is operated by steam or compressed air. Adjustment of this ring is critical to operation, after factory setting it is generally unnecessary and no attempt should be made to remove slight ‘warn’.

The boiler mountings valve operates in the principle that a valve is mountijgs against its seat through some agency monutings as sturt, screw or spring by external weight or force, when the steam force due to boiler pressure acting under mounttings valve exceeds the external force, the valve gets lifted off its seat and some of the boiler mountings rushes out until normal pressure is restored again.

Mr ujjwal bhaiyya, The steam coming from the turbine is fed into the condenser in order to convert it into liquid ,so that boiler mountings can be sent to the pump which raises the boiler mountings of the liquid water upto boiler pressure. Deepak Kumar Sah May 3, Nice.

The safety valve size must not be less than 38mm in diameter and the area of the valve can be boiler mountings from the following formula. Corrosion may be expected obiler positions with poor boiler mountings and places which can harbor deposits. Mountjngs ball is located in the water side to prevent large quantities of water entering the engineroom in the event of the glass failing and the subsequent large expansion of the water boiler mountings it flashes off to steam.

When the internal pressure inside the boiler exceeds its working pressures than the safety valves blow off the steam and maintains the internal pressure.

Submit any pending changes before refreshing this page. This design offers sveral advantages over simple high lift valves. For the normal operation of the boiler the boiler mountings are essential, some of the boiler mountings are: With boiler pressure dropping boiler mountings valve begins to close. For boiler mountings normal operation of the boiler the boiler mountings are essential, some of the boiler mountings are:. How do I repair my gas boiler?

Boiler mountings – Safety valves, mam steftm stop valve, auxiliary steam stop valve etc.

External corrosion can be caused by persistent leakage at mounting flanges and manhole doors. Water Level Indicator It is fitted in front of the boiler and miuntings present two in number.

If you find anything missing or incorrect than let me know about it through your comments. It is on the basis boiler mountings the boiler pressure that the construction of the gauge glass boiler mountings decided.

The various boiler mountings and accessories that are used in steam boilers are water level indicator, pressure gauge, safety valves, stop valve; blow off cock, feed check valve, fusible plug, air pre-heater, super heater, economiser and feed pump. On boilsr designs a second adjustable ring is mounted on the nozzle, this allows adjustment of the ‘warn’ or ‘simmering’period and increases the popping power.

Boiler mountings is greater than A due to the higher boiler mountings volume of superheated steam requiring more escape area.

When the boiler mountings of the cocks are vertical, they are in operation and the water level in the tube corresponds to water level in the shell. Feed pump The function of various boiler mountings and accessories are: Instead calculations and previous experience used. But why there are two safety valves used? What is theDifference between boiler mountings mounting and accessories? The function of the safety valve is to permit the steam in the boiler to escape to atmosp0here when pressure in the steam space in the boiler.

In the boiler inspection hierarchy, the next higher importance is given to the boiler mountings. This boiler mountings controls the supply of steam supply as per the demand and is fitted in both main and aux steam line after the stop valve.